Jetty Structural Repairs

OBJECTIVE

Multiple support structures needing structural reinforcement using engineered composites. Steel thickness lost through corrosion replaced using FUZE-Wet™ Carbon Fibre.

DESIGN DATA

  • Replace 10mm of steel 240MPa yield strength
  • Temperature 0 to 60 °C
  • FUZE-Wet™ Carbon Fibre
  • Sa 2.5 abrasive blasting surface preparation
  • 20 year design life

EXECUTION

  • Crew of 12 x FUZE Field Crew
  • 9 day shut
  • Live engineering adjustments
  • Limited landing

Outcome

The engineered solution will provide structural remediation to replace lost steel and mitigate further external corrosion.

Share: